Cart (0) Check Out


1:4 TTL/CMOS Fanout Buffer and Line Driver/Pulse Distribution Amplifier

SKU:

$ 965.00

Applications:

  • TTL/CMOS Clock Distribution
  • 1:4 Fanout Line Drivers
  • 1 PPS Distribution/IRIG-B Distribution
  • High Speed Digital Communications System Testing
  • Essential Lab Tool

Features:

  • fmax > 100 MHz
  • Drives 100 ft of cable @ 80 MHz
  • 2 ns Typical Output Rise & Fall Times
  • TTL Compatible 50 Ω or 1 kΩ Input
  • 500 ps typical channel to channel skew
  • Four in-phase 50 Ω TTL Outputs
  • BNC or SMA I/O Connectors
  • DC Coupled I/O's
  • Self-contained 1.3 x 2.9 x 2.9-in unit includes an AC/DC Adapter

Description

The PRL-414B is a 1:4 fanout 50 Ω TTL Line Driver/Pulse Distribution Amplifier.  It is intended for distribution of high-speed clock and logic signals to multiple loads via long lines.  The 50 Ω back-terminated outputs can drive long lines with or without 50 Ω load terminations; With 50 Ω load terminations, however, all outputs of the PRL-414B can drive 100 ft of 50 Ω cables at clock rates greater than 80 MHz.  In one important application, the PRL-414B is used for distributing a precision clock signal to a number of test stations in the lab.

The input resistance of the PRL-414B can be selected to be either 50 Ω or 1 kΩ by a switch.  The 1 kΩ-input is desirable when interfacing with low power circuits.  All I/Os are DC coupled and have BNC or SMA connectors.

The PRL-414B is housed in a 1.3 x 2.9 x 2.9-in. extruded aluminum enclosure and is supplied with a ±8.5 V/±1.8 A AC/DC Adapter.  A maximum of four units can share a single AC/DC adapter using the PRL-730 voltage distribution module.  If mounting is needed, a pair of the #35001420 mounting brackets can accommodate any two PRL modules of the same length.  

A block diagram showing the equivalent input and output circuits of the PRL-414B is shown in Fig. 1.

PRL-350TTL

Fig. PRL-414B Block Diagram


Application Notes:

Driving the input of the PRL-414B with a sine wave:

 

Related Products for PRL-414B

Crystal Clock Sources

  • PRL-171, Fanout Crystal Clock Source
  • PRL-172, Four-Phase Crystal Clock Source (f, f/2, f/4, f/8)
  • PRL-173, Two-Phase Crystal Clock Source (f, f/5)

RF Switches & Scanners

Frequency Dividers

  • PRL-220A, Four Phase Frequency Divider (f/2, f/4, f/8, f/16)
  • PRL-240A, Two Phase Frequency Divider (f/2, f/10)

Comparators/Sinewave Convertors

Logic Level Translators

PRL-470 High Speed Line Driver and Level Translator

Accessories

  • Mounting Brackets
  • Extra AC/DC Adapters (one included with unit)
  • Voltage Distribution Modules, for sharing AC adapters among several modules
  • Cables

SPECIFICATIONS (0° C ≤ TA ≤ 35° C)*

Symbol Parameter Min Typ Max Unit Comments
RIN LO Input Resistance Low Range 49.5 50 50.5 Ω
RIN HI Input Resistance High Range 990 1000 1010 Ω
ROUT Output Resistance 50 Ω
VIL TTL Input Low Level -0.5 0 0.5 V
VIH TTL Input High Level 2.0 2.4 5.0 V
VOL TTL Output Low Level 0 0.25 0.5 V RL=50 Ω
VOH1 TTL Output High Level 2.2 2.5 V RL=50 Ω @ DC
VOH2 TTL Output High Level 4.4 5 V RL=1 MΩ @ DC
IDC1 DC Input Currents 280 350 mA f ≤ 100 MHz
IDC2 DC Input Currents 220 250 mA f =50 MHz sq. wave(1)
VDC DC Input Voltages 7.5 8.5 12 V
VAC AC/DC Adapter Input Voltage 103 115 127 V
TPLH Propagation Delay to output ↑ 10 12 ns
TPHL Propagation Delay to output ↓ 8 12 ns
tr Rise Time (10%-90%) 2.2 3 ns f =50 MHz sq. wave
tf Fall Time (10%-90%) 1.8 3 ns f =50 MHz sq. wave
TSKEW Skew between any 2 outputs 500 1500 ps f =50 MHz sq. wave
FMAX1 Max. Clock Frequency(2) 100 120 MHz RG58C/U Cable length =3 ft
FMAX2 Max. Clock Frequency(3) 80 RG58C/U Cable length =100 ft
PWMIN Min. Pulse Width 4 ns ↑ Input
PWMIN Min. Pulse Width 6 ns ↓ Input
Size 1.3 x 2.9 x 2.9 in
Weight 5 Oz Excluding AC adapter
Shipping Weight 4 lb Including AC adapter
Unless otherwise specified, dynamic measurements are made with all outputs terminated into 50 Ω.
Notes:
(1) For sharing a single PRL-760E, ±8.5 V ±1.8 A AC/DC adapter, the total current should not exceed 1.8 A.
(2) fMAX should not exceed 120 MHz; otherwise, damage of the unit due to overheating may result.
(3) fMAX2 is measured by connecting a second PRL-414B at the end of the 100 ft. cable.

PDF datasheet

While we believe these models to be accurate, no representations are made as to accuracy or suitability for any application:

PRL-414B (BNC I/Os):

PRL-414B-SMA (SMA I/Os):