Pulse Research Lab logo
View Cart/ Check Out
Register with PRL
Mini Modular Instruments
Bias Tees
Clock Sources
Comparators/Sinewave Converters
Coupling & Termination Modules
Delay Generators
Differential Line
Drivers/Receivers
ECL/PECL Terminators
Fanout Buffers
Frequency Dividers
Logic Level Translators
Long Line Drivers
RF Power Dividers &
Splitters
RF Switches, Scanners & Gates
Signal Conditioning Kits
Variable Output
Pulse Drivers
Small Systems
Prototyping Kits & Adapters
Surface Mount Development Kits
Surface Mount Adapters (Gigadapters)
Gigadapter Motherboards
Breadboard/
Prototyping Kits
Op Amp Proto Kits
Power Sources & Modules
Enclosures & Extrusions
Accessories and Cables
About Us
Ordering Information
FAQ/Support
What's New
Contact Us
Search
Pulse Instruments
Back to Top

PRL-432/433 Specifications

Basic Lab Tools > Logic Level Translators > PRL-432/433 > Specifications
Symbol Parameter PRL-432N PRL-433N Unit
Min Typ Max Min Typ Max
RIN Input Resistance 
(low range)
122 124 126 49.5 50 50.5
VTT Input Termination Voltage (fixed)   NA   -2.2 -2 -1.8 V
IDC DC Input Current   +30
-130
+60
-150
  +30
-250
+45
-275
mA
VDC DC Input Voltage ±7.5 ±8.5 ±12 ±7.5 ±8.5 ±12 V
VAC AC/DC Adapter Input Voltage 103 115 127 103 115 127 V
TPLH Propagation Delay to output ↑   1500     1500   ps
TPHL Propagation Delay to output ↓   1500     1500   ps
TF/TF Rise/Fall times 
(20% -80%)
  400 600   NA   ps
FMAX Max clock frequency 400 600   400 600   MHz
TSKEW1 Skew between outputs   20 100   20 100 ps
TSKEW2 Skew from unit to unit   40 400   40 400 ps
  Input Connector Triax3 SMA  
  Output Connector SMA Triax3  
  Input Cables 124 Ω TP4 50 Ω Coax  
  Output Cables 50 Ω Coax 124 Ω TP4  
  Size 1.3" x 2.9" x 3.9" 1.3" x 2.9" x 3.9" In.
  Weight 7 7 Oz
*Since the high frequency signals to and from the 124 Ω I/O ports can not be measured easily, the 124 Ω I/O ports of these adapters are first cascaded using shielded twisted pair cables, Trompeter P/N PCGOW10PCG-36 or equivalent. Input signals are applied to the 50 Ω inputs of the PRL-433, and outputs of the PRL-432 are terminated into 50 Ω/-2V, using the PRL-550NQ4X, four channel ECL Terminators, connected to a 50 Ω input sampling oscilloscope.
Notes:
  1. The 50 Ω output rise and fall times were measured with both the Q and Q outputs terminated into 50 Ω/-2 V. If either output is left unterminated, both the rise and fall times will increase by approximately 15%, and output waveform degradation will occur.
  2. FMAX is measured by AC coupling a sine wave to the D input using the differential input mode (switch up). The differential outputs are first divided by eight, using the PRL-255, and then measured using the PRL-550NQ4X, four channel ECL Terminator, connected to a sampling 'scope.
  3. Trompeter P/N CBBJR79.
  4. Trompeter PCB4W10PEA-36 cable is recommended for interfacing between the CBBJR79 triax connector in the PRL-432N/433N and the twinax connector in the SONY DFC-1800.
  5. All PRL products with Triax connectors use Trompeter P/N CBBJR79, Right Angle Circuit Board Bulkhead Jack, 3-lug (Page 11 of Trompeter Mil/Aero Catalog). Any Trompeter 70-series Triax Cable Plug with 3 lugs (e.g. PL75-9, 3-lug) will mate with CBBJR79. Cable Plugs are on Page 9 of Trompeter Mil/Aero Catalog.