Pulse Research Lab logo
View Cart/ Check Out
Register with PRL
Mini Modular Instruments
Bias Tees
Clock Sources
Comparators/Sinewave Converters
Coupling & Termination Modules
Delay Generators
Differential Line
Drivers/Receivers
ECL/PECL Terminators
Fanout Buffers
Frequency Dividers
Logic Level Translators
Long Line Drivers
RF Power Dividers &
Splitters
RF Switches, Scanners & Gates
Signal Conditioning Kits
Variable Output
Pulse Drivers
Small Systems
Prototyping Kits & Adapters
Surface Mount Development Kits
Surface Mount Adapters (Gigadapters)
Gigadapter Motherboards
Breadboard/
Prototyping Kits
Op Amp Proto Kits
Power Sources & Modules
Enclosures & Extrusions
Accessories and Cables
About Us
Ordering Information
FAQ/Support
What's New
Contact Us
Search
Pulse Instruments
Back to Top

PRL-460ALPND Specifications

Basic Lab Tools > Logic Level Translators > PRL-460ALPND > Specifications

(0° C ≤ TA ≤ 35° C)*

Symbol Parameter PRL-460ALPND Unit
Min Typ Max
Rin Input Resistance 49.5 50 50.5
Rout Output Resistance (NPN emitter with 200 Ω pulldown)   N/A  
VTT "D" Input Termination Voltage (fixed) 1.18 1.30 1.43 V
VT "D" Input Termination Voltage (variable) 1.18/
1.8
1.3/
2.0
1.43/
2.2
V
VoL Output Low Level -1.85 -1.7 -1.55 V
VoH Output High Level -1.0 -0.8 -0.7 V
Vop-p Output Voltage Swing, f ≤ 700 MHz
Output Voltage Swing, f ≤ 550 MHz
  500
750
  mV
IDC DC Input Current   +90
-120
+100
-135
mA
VDC DC Input Voltage ±7.5 ±8.5 ±12 V
VAC AC/DC Adapter Input Voltage 103 115 127 V
tPLH Propagation Delay to output ↑   1.25   ns
tPHL Propagation Delay to output ↓   1.25   ns
tr/tf Rise/Fall Times (20% - 80%)*   750 950 ps
tSKEW Skew between any 2 outputs   50 120 ps
fmax Max Clock Frequency 1.25 1.5   GHz
  Size 1.3 x 2.9 x 2.9 in.
  Weight 7 Oz
* An unused complementary output must be either terminated into 50 Ω/VTT or AC coupled into a 50 Ω load; otherwise, output waveform distortion and rise time degradation will occur. Use the PRL-ACT-50 dual channel AC coupled 50 Ω Termination for terminating unused complementary outputs and the PRL-SC-104 DC Block or PRL-ACX-12dB AC coupled attenuator for connection of NECL signals to 50 Ω input oscilloscopes, if DC information is not needed. Otherwise, use the PRL-550NQ4X four channel NECL Terminators for the 50 Ω/VTT termination and for connection of NECL signals to 50 Ω input oscilloscopes.