Pulse Research Lab logo
View Cart/ Check Out
Register with PRL
Mini Modular Instruments
Bias Tees
Clock Sources
Comparators/Sinewave Converters
Coupling & Termination Modules
Delay Generators
Differential Line
Drivers/Receivers
ECL/PECL Terminators
Fanout Buffers
Frequency Dividers
Logic Level Translators
Long Line Drivers
RF Power Dividers &
Splitters
RF Switches, Scanners & Gates
Signal Conditioning Kits
Variable Output
Pulse Drivers
Small Systems
Prototyping Kits & Adapters
Surface Mount Development Kits
Surface Mount Adapters (Gigadapters)
Gigadapter Motherboards
Breadboard/
Prototyping Kits
Op Amp Proto Kits
Power Sources & Modules
Enclosures & Extrusions
Accessories and Cables
About Us
Ordering Information
FAQ/Support
What's New
Contact Us
Search
Pulse Instruments
Back to Top

PRL-435 Product Specifications

Basic Lab ToolsSwitches/Scanner/Gates > PRL-435 > Specifications

(0° C ≤ TA ≤ 35 °  C)*

Symbol Parameter PRL-435N PRL-435P Unit Comments
Min Typ Max Min Typ Max
RIN Input Resistance 49.5 50 50.5 49.5 50 50.5  
VTT Input Termination Voltage -2.2 -2 -1.8 2.7 3.0 3.3 V D input
IDC DC Input Current   -230 -250       mA  
VDC DC Input Voltage -8.5 -7.5 -12 7.5 8.5 12 V  
VAC AC/DC Adapter Input Voltage 103 115 127 103 115 127 V  
TPLH Propagation Delay to output ↑   1300 1500   1300 1500 Ps  
TPHL Propagation Delay to output ↓   1300 1500   1300 1500 Ps  
tr/tf Rise/Fall Times (20%-80%)   400 600   400 600 Ps Note (1)
TSKEW Skew between any 2 outputs   60 120   60 120 Ps  
FMAX Max clock frequency 2 2.5   2 2.5   GHz Note (2)
VCMR Common Mode Range -2.7   -0.4 2.5   4.6 V Note (3)
  Size  1.3 x 2.9 x 2.2   1.3 x 2.9 x 2.2  in.  
  Weight   5     5   Oz  

Notes: 

All dynamic measurements are made with outputs terminated into 50 Ω/VTT, using the PRL-550 Series, four channel ECL/PECL/LVPECL Terminators, connected to a 50 Ω input sampling oscilloscope.
The output rise and fall times are measured with with all inputs terminated into 50 Ω/VTT. For best performance all outputs should be terminated into 50 Ω/VTT or else AC- coupled into 50 Ω loads. If a single output is used, its complement must be terminated; otherwise output waveform distortion will occur. If one pair of complementary outputs is used, the other complementary pair may remain unterminated. Use the PRL-550 Series, four channel ECL/PECL/LVPECL Terminators, for the 50 Ω/VTT termination and for connection of ECL/PECL/LVPECL signals to 50 Ω input oscilloscopes. The PRL-ACT-50, Dual Channel AC-Coupled 50  Terminator, may also be used to provide the 50 /VTT termination. If preservation of DC levels is not required, then the PRL-SC-104, 0.1 µf DC block or the PRL-ACX-12dB, 12 dB AC-coupled attenuator, may be used to connect the NECL/PECL/LVPECL outputs to 50 Ω input instruments.
fMAX is measured using differential inputs only. The outputs are first divided by four, using the PRL-255N/P ECL/PECL Frequency Divider, and then measured using the PRL-550 Series, four channel ECL/PECL/LVPECL Terminator, connected to a sampling 'scope.
When the unit is driven by an AC-coupled sine wave signal in the differential input mode, the signal swing is symmetric with respect to VTT. The peak-to peak swing of the input signal should not exceed these Common Mode limits.

PRL-435 | Detail | Diagram | Datasheet