PRL-435 Product Specifications
|
(0° C ≤ TA ≤ 35 ° C)*
|
|
Symbol |
Parameter |
PRL-435N |
PRL-435P |
Unit |
Comments |
|
Min |
Typ |
Max |
Min |
Typ |
Max |
|
RIN |
Input Resistance |
49.5 |
50 |
50.5 |
49.5 |
50 |
50.5 |
Ω |
|
|
VTT |
Input Termination Voltage |
-2.2 |
-2 |
-1.8 |
2.7 |
3.0 |
3.3 |
V |
D input |
|
IDC |
DC Input Current |
|
-230 |
-250 |
|
|
|
mA |
|
|
VDC |
DC Input Voltage |
-8.5 |
-7.5 |
-12 |
7.5 |
8.5 |
12 |
V |
|
|
VAC |
AC/DC Adapter Input Voltage |
103 |
115 |
127 |
103 |
115 |
127 |
V |
|
|
TPLH |
Propagation Delay to output ↑ |
|
1300 |
1500 |
|
1300 |
1500 |
Ps |
|
|
TPHL |
Propagation Delay to output
↓ |
|
1300 |
1500 |
|
1300 |
1500 |
Ps |
|
|
tr/tf |
Rise/Fall Times (20%-80%) |
|
400 |
600 |
|
400 |
600 |
Ps |
Note (1) |
|
TSKEW |
Skew between any 2 outputs |
|
60 |
120 |
|
60 |
120 |
Ps |
|
|
FMAX |
Max clock frequency |
2 |
2.5 |
|
2 |
2.5 |
|
GHz |
Note (2) |
|
VCMR |
Common Mode Range |
-2.7 |
|
-0.4 |
2.5 |
|
4.6 |
V |
Note (3) |
| |
Size |
1.3 x 2.9 x 2.2 |
1.3 x 2.9 x 2.2 |
in. |
|
| |
Weight |
|
5 |
|
|
5 |
|
Oz |
|
|
Notes:
All dynamic measurements are made with outputs terminated into 50 Ω/VTT, using the
PRL-550 Series, four channel ECL/PECL/LVPECL Terminators, connected to a 50 Ω input sampling oscilloscope.
The output rise and fall times are measured with with all inputs terminated into 50 Ω/VTT. For best performance all outputs should be
terminated into 50 Ω/VTT or else AC- coupled into 50 Ω
loads. If a single output is used, its complement must be terminated; otherwise
output waveform distortion will occur. If one pair of complementary outputs is
used, the other complementary pair may remain unterminated.
Use the PRL-550 Series,
four channel ECL/PECL/LVPECL
Terminators, for the 50 Ω/VTT termination and for
connection of ECL/PECL/LVPECL signals to 50 Ω input oscilloscopes. The
PRL-ACT-50, Dual Channel AC-Coupled 50 Ω
Terminator,
may also be used to provide the 50 Ω/VTT
termination. If preservation of DC levels is not required, then the PRL-SC-104, 0.1
µf DC block or the PRL-ACX-12dB, 12 dB AC-coupled attenuator, may be used to connect the NECL/PECL/LVPECL
outputs to 50 Ω input instruments.
fMAX is measured using differential inputs only. The outputs are
first divided by four, using the PRL-255N/P
ECL/PECL Frequency Divider, and then measured using the PRL-550
Series,
four channel ECL/PECL/LVPECL Terminator, connected to a sampling 'scope.
When the unit is driven by an AC-coupled sine wave signal
in the differential input mode, the signal swing is symmetric with respect to VTT. The peak-to peak swing of the input signal should not exceed these Common
Mode limits.
|
|
|