Symbol |
Parameter |
Min |
Typ |
Max |
Unit |
Comments |
|
Rin |
Input Resistance |
49.5 |
50 |
50.5 |
Ω
|
|
|
VTT |
Input Termination Voltage |
-2.2 |
-2 |
-1.8 |
V |
Ext Clk & EN inputs |
|
IDC |
DC Input Current |
|
-520 |
-550 |
mA |
INT f=500MHz |
|
VDC |
DC Input Voltage |
-8 |
-9 |
-11 |
V |
|
|
VAC |
AC/DC Adapter Input Voltage |
103 |
115 |
127 |
V |
|
|
tPLH1 |
Propagation Delay to f output |
|
2100 |
|
ps |
From Ext Clk input |
|
tPLH2 |
Propagation Delay to f/2, f/4, or f/8 output |
|
2500 |
|
|
From Ext Clk input |
|
tPLH3 |
Propagation Delay to f output |
|
2500 |
|
|
From EN input |
|
tr/tf1 |
Rise/Fall Times (20%-80%), f
/ f
outputs |
|
500 |
800 |
ps |
Note (1) |
|
tr/tf2 |
Rise/Fall Times (20%-80%), f/n / f/n outputs |
|
750 |
850 |
ps |
Note (1) |
|
tSKEW1 |
Skew between f and f
outputs |
|
50 |
100 |
ps |
|
|
tSKEW2 |
Skew f/2
↔f/2,
f/4
↔
f/4 or f/8
↔
f/8 |
|
100 |
150 |
ps |
|
|
tSKEW3 |
Skew between f and any f/n or f/n outputs |
|
400 |
550 |
ps |
|
|
TSKEW4 |
Skew between f/n and any other f/n outputs |
|
150 |
200 |
ps |
n≠ 1 |
|
fMAX |
Max clock frequency |
1 |
1.2 |
|
GHz |
Note (2) |
|
∆ f |
Frequency Stability |
|
100 |
|
ppm |
|
| |
Frequency Jitter |
|
20 |
50 |
ps |
|
| |
Size |
|
1.3x
2.9x
3.9 |
|
in. |
|
| |
Weight |
|
7 |
|
Oz |
|
|
|
*All dynamic measurements are made with outputs terminated
into 50 Ω /-2 V,
using the PRL-550NQ4X,
four channel ECL Terminators, connected to a 50 Ω
input sampling oscilloscope.
Notes:
(1). The output rise and fall times of each channel are
measured with its complementary output terminated into 50 Ω /-2 V. An unused complementary
50 Ω
output must be either terminated into 50 Ω
/-2 V or AC coupled into a 50 Ω
load; otherwise, output waveform distortion and rise time degradation will
occur. Use the PRL-504 or PRL-508, four and eight channel ECL Termination
modules, respectively, for the 50 Ω
/-2 V termination. Use the PRL-550NQ4X
four channel ECL Terminator for the 50 Ω
/-2 V termination and for connection of ECL signals to 50 Ω
input oscilloscopes.
(2). fMAX is measured by dividing each pair of
differential outputs by four, using the PRL-255,
and then measured using the PRL-550NQ4X
four channel ECL Terminator connected to a sampling oscilloscope.
|