Applications:
- System Clock Simulation
- Low Jitter NECL Clock Source
- SONET Clock Generator
- Laser Pump Synchronization
- Scope triggering
- PRBS/BERT synchronization
- Optimizing outputs from frequency synthesizers
- Testing high-speed serial/SERDES links (GB Ethernet, eSATA, PCIe,
HT, etc)
- An Essential Lab Tool for Working with ECL Circuits
Features:
- 12 GHz typical maximum External Clock Input frequency
- f/8 to f/128 with independent 2Φ outputs
- Common Divide by 8 pre-scalar for both Φ1 and Φ2
- Φ1 output=(f/8)/(1, 2, 4 or 8), for max. ratio of 64
- Φ2 output=(f/8)/(2, 4, 8 or 16), for max. ratio of 128
- Both Φ1 and Φ2 have two pairs of complementary NECL square wave
outputs
- Single-ended AC Coupled Input with internal 50 Ω terminations
- 5 ps typical Edge Jitter
- 40 ps typical skew between f/n &
f/n NECL outputs
- Complementary DC coupled NECL Outputs drive 50 Ω loads terminated to
-2V, AC-coupled or floating 50 Ω loads
- SMA I/O Connectors
- Ready-to-Use 1.3 x 2.9 x 2.9-in. Module includes a ±8.5V AC/DC
Adapter
|
|
Description:
The PRL-257-8 is an AC-coupled input, manually programmable, two phase
frequency divider with two sets of complementary NECL outputs. It is
capable of running at input frequencies in excess of 12 GHz.
It has a common divide-by-8 pre-scalar front end followed by two banks
of independent manually programmable dividers, Φ1and Φ2. The f/8
pre-scalar output is further divided by 1, 2, 4, or 8 for the Φ1 bank via
D0 and D1 of a two-bit DIP switch, providing a maximum ratio of 64. It is
divided by 2, 4, 8 or 16 for the Φ2 bank via D2 and D3 of a second two-bit
DIP switch, providing a maximum ratio of 128. All outputs are synchronous
with the input frequency and are square waves (50% duty cycle) suitable
for driving long lines terminated into 50 Ω/-2 V or AC-coupled 50 Ω loads.
The PRL-257 is ideal for applications where a high frequency divider or
pre-scalar is needed for triggering or down-sampling. The two phases of
output enable applications requiring two different ratios from a common
reference frequency, and the 1:2 fanout feature enables system
synchronization and monitoring/triggering applications from a single
reference clock source. Applications for the PRL-257 include data
acquisition, test, measurement, R&D, and system integration.
The unit includes an AC adapter for ready-to-use convenience on the
bench or in a system. All I/O connectors are SMA. The extruded aluminum
housing is suitable for mounting with the optional brackets.
|