PRL-434A Specifications
|
(0° C ≤ TA
≤ 35° C)*
|
|
Symbol |
Parameter |
PRL-434A |
PRL-434LP |
Unit |
Comment |
|
Min |
Typ |
Max |
Min |
Typ |
Max |
|
Rin |
Input Resistance |
49.5 |
50 |
50.5 |
49.5 |
50 |
50.5 |
Ω |
|
|
VTT |
D Input Termination Voltage |
-2.2 |
-2 |
-1.8 |
1.18 |
1.30 |
1.43 |
V |
D input |
|
VT |
D
Input
Termination Voltage |
-1.17/
-2.2 |
-1.3/
-2 |
-1.43/
-1.8 |
1.18/
1.8 |
1.3/
2.0 |
1.43/
2.2 |
V |
D
input |
|
VIL |
Input Lo Voltage |
-1.95 |
-1.6 |
-1.48 |
1.35 |
1.48 |
1.67 |
V |
|
|
VIH |
Input Hi Voltage |
-1.13 |
-0.9 |
-0.81 |
2.08 |
2.28 |
2.42 |
V |
|
|
VOL |
Output Lo Voltage |
-1.95 |
-1.6 |
-1.48 |
1.35 |
1.48 |
1.61 |
V |
|
|
VOH |
Output Hi Voltage |
-1.13 |
-0.9 |
-0.81 |
2.15 |
2.28 |
2.51 |
V |
|
|
VOP-P |
Output peak-to-peak swing
- f ≤ 1 GHZ
- 1 GHZ ≤ f ≤ 2 GHz
- 2 GHz ≤ f ≤ 3.5 GHz
- f = 4 GHz
|
|
|
|
375
300
100 |
400
350
140
120 |
|
mV
mV
mV
mV |
|
|
IDC |
DC Input Current |
|
-360 |
-385 |
|
320 |
350 |
mA |
|
|
VDC |
DC Input Voltage |
-7.5 |
-8.5 |
-12 |
7.5 |
8.5 |
12 |
V |
|
|
VAC |
AC/DC Adapter Input Voltage |
103 |
115 |
127 |
103 |
115 |
127 |
V |
|
|
TPLH |
Propagation Delay to output
↑ |
|
1100 |
1500 |
|
1100 |
1500 |
ps |
|
|
TPHL |
Propagation Delay to output
↓ |
|
1100 |
1500 |
|
1100 |
1500 |
ps |
|
|
tr/tf |
Rise/Fall Times (20%-80%) |
|
250 |
360 |
|
220 |
300 |
Ps |
Note (1) |
|
TSKEW |
Skew between any 2 outputs |
|
20 |
75 |
|
20 |
75 |
Ps |
|
|
FMAX |
Max clock frequency |
3.5 |
4.0 |
|
3.5 |
4.0 |
|
GHz |
Note (2) |
|
VCMR |
Common Mode Range |
-2.15 |
|
-0.4 |
2.0 |
|
3.3 |
V |
Note (3) |
| |
Size |
1.3 x
2.9 x 2.9 |
1.3 x
2.9 x 2.9 |
in. |
|
| |
Weight |
5 |
5 |
Oz |
|
| |
Shipping Weight incl. AC adapter |
3 |
3 |
lb. |
|
|
*All dynamic measurements are made with outputs terminated into 50 Ω
/-2 V, using the PRL-550NQ4X,
four channel ECL Terminator, connected to a 50 Ω input sampling
oscilloscope.
Notes:
(1). The output rise and fall times of each channel are measured with its
complementary output terminated into 50 Ω/-2 V. An unused
complementary 50 Ω output must be either terminated into 50 Ω/-2 V
or AC coupled into a 50 Ω load; otherwise, output waveform distortion and
rise time degradation will occur. Use the PRL-ACT-50 Dual Channel, AC Coupled 50 Ω
Terminator for terminating unused outputs.
(2). fMAX is measured using differential inputs only. Each pair
of differential outputs are first divided by four, using the PRL-255,
and then measured using the PRL-550NQ4X,
four channel ECL Terminator, connected to a sampling 'scope. 3.0 GHz guaranteed
fMAX is currently limited by production test equipment.
(3). When the unit is driven by an AC coupled sinewave signal in the
differential input mode, the signal swing is symmetrical with respect to -2 V.
The peak-to peak swing of the input signal should not exceed these Common Mode
limits.
|
|
|