PRL-431N Specifications
|
(0° C
≤ TA
≤ 35° C)*
|
|
Symbol |
Parameter |
PRL-431N |
PRL-431P |
Unit |
Comments |
|
Min |
Typ |
Max |
Min |
Typ |
Max |
|
Rin |
Input Resistance |
49.5 |
50 |
50.5 |
49.5 |
50 |
50.5 |
Ω |
|
|
VTT |
D Input Termination Voltage (fixed) |
-2.2 |
-2 |
-1.8 |
2.7 |
3 |
3.3 |
V |
|
|
VT |
D
Input Termination
Voltage (variable) |
-1.17/
-2.2 |
-1.3/
-2 |
-1.43/
-1.8 |
3.33/2.7 |
3/3.7 |
4.07/3.3 |
V |
|
|
VIL |
Input Lo Voltage |
-1.95 |
-1.6 |
-1.48 |
3.05 |
3.4 |
3.52 |
V |
|
|
VIH |
Input Hi Voltage |
-1.13 |
-0.9 |
-0.81 |
3.87 |
4.1 |
4.19 |
V |
|
|
VOL |
Output Lo Voltage |
-1.95 |
-1.7 |
-1.48 |
3.0 |
3.15 |
3.3 |
V |
|
|
VOH |
Output Hi Voltage |
-1.13 |
-0.9 |
-0.81 |
3.4 |
3.55 |
3.8 |
V |
|
|
IDC |
DC Input Current |
|
-165 |
-180 |
|
160 |
180 |
mA |
|
|
VDC |
DC Input Voltage |
-7.5 |
-8.5 |
-12 |
7.5 |
8.5 |
12 |
V |
|
|
VAC |
AC/DC Adapter Input Voltage |
103 |
115 |
127 |
103 |
115 |
127 |
V |
|
|
tPLH |
Propagation Delay to output ↑
|
|
750 |
950 |
|
750 |
950 |
ps |
|
|
tPHL |
Propagation Delay to output ↓
|
|
750 |
950 |
|
750 |
950 |
ps |
|
|
tr/tf |
Rise/Fall Times (20%-80%) |
|
400 |
550 |
|
400 |
550 |
ps |
Note (1) |
|
tSKEW |
Skew between any 2 outputs |
|
20 |
75 |
|
20 |
75 |
ps |
|
|
fMAX |
Max clock frequency |
2.5 |
3 |
|
2.5 |
3 |
|
GHz |
Notes (2,3) |
|
VCMR |
Common Mode Range |
-2.7 |
|
-0.4 |
2.5 |
|
4.6 |
V |
|
| |
Size |
1.3 x 2.9 x 2.2 |
1.3 x 2.9 x 2.2 |
in. |
|
| |
Weight |
5 |
5 |
Oz |
|
|
*All measurements are made
with outputs terminated into 50 Ω/VTT,
using the PRL-550NQ4X
or PRL-550PQ4X four channel ECL/PECL Terminators, connected to a
50 Ω input sampling oscilloscope.
Notes:
The output rise and fall times are measured with with all inputs terminated into 50 Ω/VTT. For best performance all outputs should be
terminated into 50 Ω/VTT or else AC- coupled into 50 Ω
loads. If a single output is used, its complement must be terminated; otherwise
output waveform distortion will occur. If one pair of complementary outputs is
used, the other complementary pair may remain unterminated.
Use the PRL-550 Series,
four channel ECL/PECL/LVPECL
Terminators, for the 50 Ω/VTT termination and for
connection of ECL/PECL/LVPECL signals to 50 Ω input oscilloscopes. The
PRL-ACT-50, Dual Channel AC-Coupled 50 Ω
Terminator,
may also be used to provide the 50 Ω/VTT
termination. If preservation of DC levels is not required, then the PRL-SC-104, 0.1
µf DC block or the PRL-ACX-12dB, 12 dB AC-coupled attenuator, may be used to connect the NECL/PECL/LVPECL
outputs to 50 Ω input instruments.
(2). fMAX is measured by AC coupling a sine wave to
the D input using the differential input mode (switch up). The
differential outputs are first divided by four, using the PRL-255N
or PRL-255P, and
then measured using the PRL-550NQ4X
or PRL-550PQ4X, four channel ECL/PECL
Terminators,
connected to a sampling scope.
(3). fMAX is specified for SMA models.
BNC versions are slower.
VTT is nominally
-2.0 V for ECL, +3.0 V for PECL, and +1.3 V for LVPECL. VBB is nominally -1.3 V