PRL-480
Specifications
|
(0° C
≤ TA
≤ 35° C)*
|
|
Symbol |
Parameter |
Min |
Typ |
Max |
Unit |
Comments |
|
Rin |
Input Resistance |
49.5 |
50 |
50.5 |
Ω |
|
|
VTT |
Input Termination Voltage (fixed) |
-2.2 |
-2 |
-1.8 |
V |
D Inputs |
|
VT |
Input Termination Voltage (variable) |
-1.17/
-2.2 |
-1.3/
-2 |
-1.43/
-1.8 |
V |
D
Inputs |
|
+ICC |
Positive DC Input Current |
|
25 |
30 |
mA |
|
|
-IEE |
Negative DC Input Current |
|
-420 |
-450 |
mA |
|
|
VDC |
DC Input Voltage |
±7.5 |
±8.5 |
±12 |
V |
|
|
VAC |
AC/DC Adapter Input Voltage |
103 |
115 |
127 |
V |
|
|
tPLH |
Insertion propagation Delay to output
↑ |
|
2500 |
|
ps |
D1-D7 set to 0 |
|
tPHL |
Insertion propagation Delay to output
↓ |
|
2500 |
|
ps |
D1-D7 set to 0 |
|
Dt |
Step Delay
- D1 High
- D2 High
- D3 High
- D4 High
- D5 High
- D6 High
- D7 High
|
|
-
17.5
-
35
-
70
-
140
-
280
-
560
-
1120
|
|
ps |
|
|
tr/tf |
Rise/Fall
Times (20%-80%) |
|
700 |
900 |
ps |
Note (1) |
|
tSKEW |
Skew between Q & Q
Outputs |
|
40 |
80 |
ps |
|
|
tSKEW |
Skew between Q1 & Q2 Outputs |
|
40 |
80 |
ps |
D1-D7 set to 0 |
|
fMAX |
Max clock frequency |
1 |
1.2 |
|
GHz |
Note (2) |
|
VCMR |
Common Mode Range |
-2.7 |
|
-0.4 |
V |
|
| |
Size |
1.3 x 2.9 x 3.9 |
in. |
|
| |
Weight |
8 |
Oz |
|
|
*All measurements are made with outputs terminated into
50 Ω/-2 V, using the PRL-550NQ4X, four-channel ECL Terminators, connected to a
50 Ω input sampling oscilloscope.
Notes:
(1). The output rise and fall times are measured with both the
Q and Q outputs terminated into
50 Ω/-2V. An unused complementary output must be
either terminated into 50 Ω /-2 V or AC coupled into a 50 Ω load; otherwise,
output waveform distortion and rise time degradation will occur. Use the PRL-504
or PRL-508, four and eight channel ECL Termination modules, respectively, for
the 50 Ω/-2V termination. Use the PRL-550ND4X and PRL-550NQ4X, two and four channel ECL Terminators, respectively, for the
50 Ω/-2V termination and for connection of ECL signals to 50 Ω
input oscilloscopes.
(2). fMAX is measured by AC coupling a sine wave to the
D input using the differential input mode (switch up). The differential outputs
are first divided by four, using the PRL-255, and then measured using the
PRL-550NQ4X, four channel ECL Terminators, connected to a sampling 'scope.
|
|
|