PRL-174ANT Specifications
|
(0° C
≤ TA
≤ 35° C)*
|
|
Symbol |
Parameter |
Min |
Typ |
Max |
Unit |
Comments |
|
IDC |
DC Input Current |
|
+185/-700
45 |
+200/-750
55 |
mA |
±8.5 V
+17 V |
|
VDC |
DC Input Voltage |
±7.5
+17 |
±8.5
+18 |
±12
+20 |
V |
|
|
VAC |
AC/DC Adapter Input Voltage |
103 |
115 |
127 |
V |
|
|
tr/tf1 |
Rise/Fall Times (20%-80%), NECL outputs |
|
400 |
750 |
ps |
Note 1 |
|
tr/tf2 |
Rise/Fall Times (10%-90%),
TTL outputs |
|
1000 |
1300 |
ps |
f/2n only, Note 2 |
|
tSKEW1 |
Skew f
↔ f outputs |
|
30 |
60 |
ps |
|
|
tSKEW2 |
Skew f/n ↔ f/n, NECL outputs |
|
50 |
100 |
ps |
|
|
tSKEW3 |
Skew f/n ↔ f/n,
TTL outputs |
|
500 |
850 |
ps |
|
|
TSKEW4 |
Skew f/n
ECL ↔ f/n TTL outputs |
|
1000 |
1250 |
ps |
n≠1 |
|
fMAX |
Max internal VCO clock frequency |
1350 |
1375 |
1400 |
MHz |
|
|
fMIN |
Min internal VCO clock frequency |
|
570 |
600 |
MHz |
|
|
fMAX/fMIN |
|
2 |
2.3 |
|
|
|
|
f/NMAX |
Max NECL output frequency
Max TTL output frequency |
675
200 |
687.5
250 |
|
MHz |
Note 2 |
|
f/NMIN |
Max Output frequency |
1.12 |
1.2 |
|
MHz |
|
|
∆f1 |
Short- term Frequency Drift over 1/2 hr. |
|
100 |
250 |
ppm |
∆TA < 2° C (3) |
|
∆f2 |
Long- term Frequency Drift over 12 hrs. |
|
250 |
500 |
ppm |
∆TA < 2° C |
|
∆f3 |
Initial Frequency Drift w/in 1 min. after power-on |
|
5000 |
|
ppm |
∆TA < 2° C |
| |
Frequency Jitter, peak-to-peak |
|
20 |
25 |
ps |
|
| |
Size |
1.3 x
2.9 x 8.1 |
in. |
|
| |
Weight |
10 |
Oz |
|
|
*All dynamic NECL measurements are made with outputs terminated into 50 Ω/-2 V, using the PRL-550NQ4X, four channel NECL Terminators, connected to a
50 Ω input sampling oscilloscope. TTL inputs are terminated with 50 Ω.
Notes:
(1) The rise and fall times of the NECL outputs are measured with all outputs terminated into 50 Ω/-2 V. An unused complementary output must be either terminated into 50 Ω/-2 V
or AC coupled into a 50 Ω load; otherwise, output waveform distortion and rise time degradation will occur. Use the
PRL-550ND4X or PRL-550NQ4X, two or four channel NECL Terminator, for the 50 Ω/VTT termination and for connection to 50 Ω input oscilloscopes, when DC coupling is necessary. Otherwise, use the
PRL-ACT-50, dual AC coupled 50 Ω-termination for terminating unused outputs and the
PRL-SC-104, 0.1 µf DC block, for AC coupling into a 50 Ω load or scope. The
PRL-ACX-12dB, AC coupled 12 dB attenuator, can also be used either for termination or for connection to an oscilloscope.
(2) In Normal mode, the pulse width of the f/n outputs is equal to the period of the VCO frequency, varying from
741 ps to 1.67 ns as the VCO frequency is changed from 1.35 GHz to 600 MHz. In Square Wave mode (Bit 9 up), the pulse width is
twice the f/n clock period. For optimum performance, use the square wave output mode for TTL
outputs. Beyond 250 MHz, reduced swings of the TTL outputs no longer comply with the standard Hi and Lo levels of 2 V and 0.8 V, respectively.
(3) After 1 hour warm up and VCO out frequency f≥650 MHz. For f <
650 MHz,
∆f1 and
∆f2 may exceed 250 ppm and 500 ppm, respectively.
|
|
|