Q5: What does
a typical ECL input circuit look like?
A5: Instead of describing each ECL, LVECL, PECL or
LVPECL input circuit separately, we shall focus on the generalized "ECL"
circuit, with a VCC supply and a VEE supply.
The basic input circuit of an ECL device is simply the base of a NPN
transistor. For a device installed inside a piece of equipment, however, some
form of an input termination is always used. The most common input configuration
is one that has a 50 Ω termination into VTT, where
VTT
is defined as VCC- 2 V. This configuration is used for either single-ended or
differential inputs, as shown in Fig. 2A.

The second configuration consists of a
single floating resistor connected between the differential inputs of an ECL device, as shown in Fig. 2B.

The most common value of this resistor is 124 Ω. Other values such as 75 Ω, 78 Ω,
and 100 Ω are also used. The third consists of two
resistors in series, and the series combination is connected across the
differential inputs of the ECL device, and the junction of the resistors is bypassed by a capacitor to ground, as shown in Fig. 2C. Other configurations are
also used.

The reason why ECL input circuits inside a piece of equipment must always be
terminated as described above has to do with matching impedance. Without proper
input terminations, it would not be possible to interconnect various equipment
together.
For a listing of PRL products using ECL Circuits, click
here
Q6: What does
a typical ECL Output Circuit look like?
A6: As shown in Fig. 1 earlier, the ECL output
circuit consists of an open NPN emitter, and it was also pointed out that a
pull-down resistor is needed in order to turn on the emitter follower. In a
piece of equipment provided with ECL outputs, however, internal pull-down
resistors may or may not be included. Since pull-down resistors consume power,
the equipment manufacturers dont put them in unless they have to. If it is
not labeled, it may be assumed that they are not included. As we shall see in
the following discussion (Question 7), ECL outputs without the proper internal pull-down
resistors cannot drive AC coupled loads or floating loads.
For a listing of PRL products using ECL Circuits, click
here
Q7:
How to Drive ECL Inputs connected to 50 Ω/VTT
Terminations?
A7: There are two cases to consider. The first involves using an ECL output
device as the driver, and the second uses a 50 Ω
output generator. In the first case, there is nothing to adjust, and the
question is whether or not the I/O are compatible. In the second case, the
generator output Hi and Lo levels must be adjusted so that they produce the
correct levels at the input of the receiving device. In the following
discussion, the standard ECL levels will be used. The basic principle is
applicable to LVECL, PECL and LVPECL as well.
Case I: The driver is an ECL device.
For a single input configuration, it can be connected directly to the open
emitter of an ECL output connector via a 50 Ω cable,
as shown in Fig. 3.

It is seen that the 50 Ω resistor
connected to 2 V supplies the current to the open emitter, and, therefore, no
pull-down resistor is needed from the driver emitter follower. Note that the
unused input is assumed to be connected to a bias voltage VBB
internally as shown. If a pair of differential input connectors are present,
either the unused input must be connected to VBB externally or both
inputs must be driven using a pair of complementary signals.
Although no calculation is required for interconnecting the I/Os in this
case, the simple calculation given below is helpful in seeing why the pull-down
resistor plays an important part. Assuming the "hi" and "lo"
logic levels developed under this "heavy loading" condition to be 0.95 V
and 1.75 V, respectively, the output currents from the driver circuit can be
easily calculated to be:
IOH=(2-0.95)V/50 Ω
=21 mA and
IOL=(2-1.75)V/50 Ω
=5 mA
The exact values of the currents are not important, as long as they are
positive numbers, because an NPN emitter can only source current but not sink
current. An ECL output with internal pull-down resistor can also drive this type
of input circuit. It should be noted that a 50 Ω cable
must be used for this configuration because the load at the end of the cable is
50 Ω. For more discussion see Transmission Line
FAQs.
Case II: The driver is a 50 Ω-output Generator
Fig. 5 shows an equivalent circuit of a 50 Ω-output pulse generator connected to a 50 Ω/-2 V input
terminated ECL circuit.

In order to produce a set of Hi and Lo levels equal to
-0.8 V and 1.6 V, respectively, at the ECL device input, the open circuit Hi
and Lo levels of the pulse generator should be set to +0.4 V and 1.2 V,
respectively. This is easily verified by calculating the current in each logic
state using Fig. 5. Often, for convenience, the Lo level of 2 V is used.
However, the 0.8 V/-2 V levels are not symmetrical with respect to the ECL
threshold voltage VBB, which has a typical value of 1.3 V. The net
result of using this set of input voltages is that the propagation delays of the
output rising and falling edges will not be exactly the same.
The output levels of the 50 Ω-output Generator
required for LVECL, PECL and LVPECL are given in A4, Table
I. It is important to
note that ECL and LVECL are compatible, but PECL and LVPECL are not.
PRL Products using ECL Circuits:
Our line of Logic Level
Translators
The following Logic Function
Modules:
|